|

Build Your Online Product Catalogs?
Product Name: |
HIVERT HVAC Special Medium Voltage Drive
|
Supply Ability: |
|
Related proudcts |
|
Specifications |
see description |
Price Term: |
TT,LC |
Port of loading: |
|
Minimum Order |
1 |
Unit Price: |
100,000 ~5,000,000 |
|
Variable Frequency Drive Applications in HVAC Systems
Hiconics's VFD HVAC inverters are electrical equipment that work together with medium and large central ACs to achieve energy-saving effects. HVAC converters can reduce the mechanical i***ct inside the ACs to increase service life, stabilize the operation of the unit, reduce noise, and improve user comfort.
We also care about your experience:
- Online Cloud Service
- High resolution touch screen interface, simple operation
- Intelligente system: Full digital control system a variety of control mode, without harmonic
Different Models of HIVERT Variable Frequency Drive HAVC Special Medium Voltage Drive 10kV/315-2000kW Special Medium Voltage Drive ¤ 10kV/315-2000kW
Composition of HIVERT HVAC Special Medium Voltage Drive HVAC General Medium Voltage Drive is composed of 3 main parts: 1. transformer cabinet 2. power-cell cabinet 3. control system
Composition of HIVERT HVAC Special Medium Voltage Drive
Main Features of HVAC Special Medium Voltage Drive Phase Locked Loop Technology
The software phase-locked loop technology widely used in the field of new energy is applied to the high-voltage vfd inverter speed tracking algorithm, and a closed-loop feedback system is adopted to effectively suppress the influence of harmonic disturbance on the phase-locking accuracy. The speed tracking algorithm has built-in modules such as pair limiting, filtering, compensation, and adaptive amplification to achieve accurate, fast, widerange, and speed tracking effects.
Instant Power Loss
When the inverter ***ects that the grid voltage drops, the inverter reduces the output frequency and runs at a reduced speed. At this time, the motor rotates ahead of time and is in an electric state to charge the grid side. Within the instantaneous power failure time, the inverter runs normally; after the instantaneous power failure time, the power grid will not resume power supply, and it will be treated as a medium voltage power loss. |
Company: |
Hiconics Eco-energy Technology Co., Ltd.
|
Contact: |
hiconics- global |
Address: |
"NO.3 Boxing 2nd Road, Economic and Technological Development Zone, Daxing District, 100176, Beijing, China" |
Postcode: |
|
Tel: |
010-59180185 |
Fax: |
|
E-mail: |
|
|
|
|